![]() | COMMERCIAL ENGINE STANDARD PRACTICES MANUAL | Dated: 04/01/2006 |
SPM 70-00-99 S1143 - LIGHT DUTY ALKALINE CLEANER - C04-164 | ||
TASK 70-00-99-801-143 |
1 . | Composition. |
|
2 . | Preparation. |
Subtask 70-00-99-809-259 |
WARNING: |
|
A. | Fill tank two-thirds full with water. |
B. | Add alkaline cleaner C04-164 product slowly and carefully while stirring the solution to mix. |
C. | Fill tank with water to working level. |
D. | Stir solution again to mix. |
3 . | Check. |
Subtask 70-00-99-809-260 |
E. | Determine the concentration of the solution as follows: |
|
F. | Follow the manufacturer's control procedures to maintain the solution within check limits. |
4 . | Regeneration. |
Subtask 70-00-99-809-261 |
G. | Every day, remove surface scum from the tank. |
H. | Maintain solution within check limits by the addition of appropriate products. |
I. | Losses through evaporation will be made up by filling the tank with water up to working level on a daily bases. |
J. | Replace the solution if it loses its effectiveness. |