![]() | COMMERCIAL ENGINE STANDARD PRACTICES MANUAL | Dated: 04/01/2006 |
SPM 70-00-99 S1144 - LIGHT DUTY ALKALINE CLEANER - C04-165 | ||
TASK 70-00-99-801-144 |
1 . | Composition. |
|
2 . | Preparation. |
Subtask 70-00-99-809-262 |
WARNING: |
|
A. | Fill tank two-thirds full with water. |
B. | Add Cee-Bee A-7X7 product slowly and carefully while stirring the solution to mix. |
C. | Fill tank with water to working level. |
D. | Stir solution again to mix. |
3 . | Check. |
Subtask 70-00-99-809-263 |
E. | Make operational check per the following: |
|
F. | Determination of the Cee-Bee A-7X7 Quantity. Use process materials and procedures as recommended by McGean-Rohco, Inc., Cee-Bee Division. Refer to the List of Suppliers in Step 4 of 70-80-00. |
4 . | Regeneration. |
Subtask 70-00-99-809-264 |
G. | Remove scum layer from top of tank at least every day, preferably every shift, and also as needed. |
H. | Maintain solution strength within check limits. Increase strength (if necessary) by adding concentrate as required per calculated amount from analysis procedure. Decrease strength by diluting with water. |
I. | Recover evaporation losses by filling tank to "working level" with water on daily basis. |