TASK 70-32-07-250-001
1 . General.
NOTE:
SAE Aerospace Standard AS4787 can be used in conjunction with this procedure. AS4787 is considered equivalent to this procedure, but lacks specific inspection requirements for GE Aircraft Engines CF6 products. Therefore both documents will be necessary if inspecting the parts per AS4787.
A.This practice describes the equipment and processes used for eddy current inspection of circular holes in engine parts. These techniques are used to detect flaws or discontinuities at, or near, the surface of metallic parts which may be detrimental to the part life or limit its intended use.
B.Only qualified operators specifically designated, trained and approved to perform a specified inspection shall perform that test. Operators must be capable of performing equipment calibrations, carrying out the intended inspection and be capable of acceptable interpretation of output test data before his acceptance or rejection of hardware in accordance with an inspection procedure.
C.There are three inspection methods:
Method A (High Speed) is in Subtask 70-32-07-250-011, High Speed Eddy Current Inspection (Method A).
Method B (Slow Speed) is in Subtask 70-32-07-250-012, Slow Speed Eddy Current Inspection (Method B).
Method C (High Speed with Electronic Data Acquisition) is in Subtask 70-32-07-250-013, High Speed Eddy Current Inspection with Electronic Data Acquisition and Storage (Method C).
2 . High Speed Eddy Current Inspection (Method A).
Subtask 70-32-07-250-011
D.Method A: High Speed Eddy Current Inspection.
(1)Scope.
(a)This document describes the equipment, technique and procedure necessary to do a 2 MHz high speed eddy current inspections of circular holes in aircraft engines hardware for the detection of cracking. A Service Bulletin or Engine/Shop Manual procedure is required for the detailed information needed for inspection of specific parts.
(b)This document describes the general procedure and equipment which have been approved for the performance of high speed eddy current hole inspections. Exceptions to this procedure may be required for specific cases where the procedure or equipment described in this procedure cannot be used or is not appropriate. Such exceptions should be obtained in writing from GE Aircraft Engines.
(2)Applicable Documents.
(a)Instruction manuals or other information provided by equipment manufacturers.
(b)The appropriate Service Bulletin or Engine/Shop Manual inspection for the hardware inspection.
(c)Kit preparation and quality assurance plan, M & FQT Procedure 1480 (applies to GEAE/QTC only).
(3)Personnel Requirements.
(a)Personnel performing this inspection shall be certified in accordance with one of the following:
1National Aerospace Standard 410 (NAS 410), which replaces MIL-STD 410
2American Society of Nondestructive Testing specification ASNT-TC-1A (ASNT-TC-1A)
3Air Transport Association Specification No. 105 (ATA 105)
4Comite Sectoriel Aeronautique Cofrend (COSAC)
5A locally approved certification program.
(b)Personnel performing this inspection should receive practical training in the use of this procedure and must demonstrate proficiency in calibration of the inspection equipment, inspection of hardware, and evaluation of indications before the authority to accept and reject hardware is delegated.
(c)Any training which may be provided regarding the performance of this inspection does not imply that the personnel who receive that training have met the requirements for inspector certification in accordance with paragraph (3)(a)..
(4)Equipment Requirements.
NOTE:
Items (a) through (b) are to be supplied by the inspection site.
NOTE:
Items (c) through (i) can be obtained from GE Aircraft Engines. The correct service bulletin or shop manual inspection procedure will specify (by GE kit number) the necessary tooling requirements.
NOTE:
Get items (c) through (i) from:
GE Aircraft Engines, QTC. Refer to the List of Suppliers in Step 4 of 70-80-00.
(a)The eddy current instruments listed in Table 1 are approved for use with this procedure.
NOTE:
Nortec NDT 19 Instruments having serial numbers 314 and below will not function correctly with the high speed rotor and cannot be used. Instruments having serial numbers 315 and higher may be used if an internal adjustment is made.
NOTE:
This is to be done by the manufacturer. All NDT 19E models should function without internal adjustments.
NOTE:
The Hocking Phasec 1.1 must have the appropriate software to ensure that the correct filtering is available to perform high speed bolthole inspections at the appropriate inspection sensitivity and noise levels. To determine if the unit has the correct software, the filter display must show actual frequency values (in Hz). Highlighting the High Pass (HP) filter field on the instrument and advancing through all the frequency settings, should show the following HP filters: DC, 2 Hz, 25 Hz, 100 Hz, and 500 Hz. If these values cannot be displayed, and instead, “STD”, 1, 2, 3, 4, and 5 are displayed, then the instrument does not have the software needed to perform this inspection.
 
Initial Instrument Control Settings - Table 1
 
Control Description
Setting
 
Rohmann Elotest B1:

 
Frequency
2.0 MHz
 
Gain
60 dB
 
X Axis Gain
0 dB
 
Y Axis Gain
0 dB
 
Preamplifier
Maximum value possible
 
Bandwidth
HF
 
Phase

 
Dot position
0/0
 
Filter type
BP (Band pass)
 
Filter frequency
800 Hz
 
Rohmann Elotest B1V3 and B1V4:

 
Frequency
2.0 MHz
 
Bandwidth
HF
 
Gain
58/58 dB
 
Y-Spread
0
 
X-Spread
0
 
Phase
328°
 
Filter: High Pass
400 Hz
 
Filter: Low Pass
1.25 kHz
 
Rohmann Elotest B2:

 
Sweep: Display (Switch)
X-Y
 
Sweep: Fine
N/A
 
Sweep: Coarse
N/A
 
HP Filter: Hz
33
 
HP Filter: Range
X10
 
HP Filter: BP
0
 
HP Filter: Switch
On
 
Sensitivity: Y x 2
0
 
Sensitivity: dB
05
 
Phase
4.0
 
Frequency: Switch
Display
 
Frequency: Fine
Adjust as required to get 2000 kHz
 
Frequency: Range
5
 
Filter
HF
 
LPF
1 kHz
 
Driver circuit
-12
 
Receiver pre-amp
30 dB
 
Forster Defectoscope SD 2.832:

 
Power (1/0)
1 (On)
 
Filter (TP/HP)
5 (160 Hz High Pass)
 
Sensitivity
26.5 dB
 
Frequency
200 kHz (Use Exp. button)
 
Phase
184
 
1p
1
 
U1
0
 
Yo (Y Position)
50
 
Xo (X Position)
0
 
Intense
As needed
 
XY (dB Spread)
0
 
Store time
1
 
Display
Impedance mode (TR)
 
Signal display
Off (0)
 
X1, X10 Switch
X10
 
I/O Switch on motor
As desired
 
Forster Defectoscope SD 2.833:

 
Drive
25 Ohms
 
Att.
0 dB
 
Frequency
2 MHz
 
Phase
218
 
Gain
66 dB
 
Y Spread
0 dB
 
X Spread
0 dB
 
HP Filter
150 Hz
 
LP Filter
1 kHz
 
Time
0.1s
 
Hocking 2200:

 
RPM
3000
 
Display
XY
 
Persist
1 S
 
CH 1 Frequency
2 MHz
 
CH 1 Gain
50 dB
 
CH 1 X:Y
0.0 dB
 
Angle
83
 
Low Pass Filter
2000 Hz
 
High Pass Filter
200 Hz
 
IMP Gain
+20 dB
 
X-Pos 1
0
 
Y-Pos 1
0
 
Hocking Phasec 1.1:

 
Power
On
 
Frequency
2 MHz
 
Gain
30 dB
 
Phase
300
 
Store
---
 
Hi-Pass Filter
250
 
Lo-Pass Filter
1500
 
I/P
---
 
Horizontal position
0
 
Vertical position
0
 
V/H Ratio
1:1
 
Sweep
Off
 
RPM
1500
 
Staveley Nortec 19/19e/19ell:

 
Power
On
 
Display
Frequency 1
 
Sweep
Off
 
Program
01
 
Memory 2
Off
 
Latch
Off
 
Frequency
2000 kHz
 
Gain (Horizontal and Vertical)
60.000
 
Position
128 (50%)
 
Angle
00
 
High Pass Filter
200
 
Low Pass Filter
500
 
SP 02 (Probe drive)
Mid
 
SP 03
Off
 
SP 01, 04, 05, 07
Optional
 
Continuous null
Off
 
Display erase
As required
 
Null
As required
 
F1/F2 (Frequency)
Frequency 1
 
C/F (Coarse/Fine)
As required
 
Staveley Nortec 24:

 
Frequency
2 MHz
 
Gain
60 dB
 
H Gain
72.0
 
V Gain
72.0
 
HP Filter
200
 
LP Filter
500
 
Display
60.000
 
Sweep
Off
 
V Position
50%
 
H Position
50%
 
Screen
---
 
Persist
Off
 
Sweep Erase
On
 
Display Erase
1 s
 
Graticule
On
 
Scanner

 
Sweep
Off
 
Scan RPM
1200
 
Staveley Nortec 2000 series

 
Frequency
2.0 MHz
 
Angle
187°
 
H Gain
60 dB
 
V Gain
60 dB
 
Probe Drive
Mid
 
LP Filter
500
 
HP Filter
200
 
HPF Pole
2-Pole
 
Sweep
Off
 
V Position
50%
 
H Position
50%
 
Persist
Off
 
Sweep Erase
As required
 
Display Erase
As required
 
Graticule
On
 
Scan RPM
1500
 
Uniwest US-454/454A EddyView
 
Frequency
2 MHz
 
F1 Gain
25.7 dB
 
F1 Rot
29 Deg
 
Freq 2
Off
 
Drive
High
 
LP Filter
1.25 kHZ
 
HP Filter
400 Hz
 
X Sens
0.5 V/Div
 
Y Sens
=X
 
X Null point
0.0 Div
 
Y Null point
0.0 Div
 
EC disp
I - Plane
 
Auto CLR
2 sec (as required)
 
Persist
Off
 
Nortec 500D, 500S, Series and Spitfire (Cable PN 9122090.00) or Mini Mite Scanner (Cable PN 9122089.02)
 
Main:

 
Frequency
2 MHz
 
Angle
8.0
 
Gain
56.3 dB
 
PreAmp
Off
 
Cont. Null
Off
 
Balance
Off
 
LP FLT
500 Hz
 
HP FLT
200 Hz (adjust as needed to get equal legs)
 
Display: Screen Set-Up
 
H-Pos
50%
 
V-Pos
50%
 
Dot/Box
Dot
 
D-Erase

 
Persist
Off
 
Disp. Erase
1.0 Sec (as needed)
 
Sweep Erase
Off (as needed)
 
Graticule
On
 
Main DSP
F1
 
Scan:

 
Sweep Mode
Off
 
RPM
1500
 
Sync. Ang.
0
 
Set-Up: Instrument Set-Up

 
Probe Drive
Mid
 
Ang. Step
1.0
 
Freq. Mode
Single (500D)
 
Vmix Gain
0
 
Hmix Gain
0
 
Nortec 600 Series and Spitfire (Cable PN 9122090.00) or Mini Mite Scanner (Cable PN 9122089.02)
 
Main/Filter Set-Up - 1st Screen Freq 1:
 
Frequency
2 MHz
 
Angle
146.0
 
Gain H
55.0 dB (Keep the Gain Settings in Same Value)
 
Gain V
55.0 db
 
Main/Filter Set-Up - 2nd Screen Filter:
 
LP FLT
1500 Hz
 
HP FLT
500 Hz (adjust as needed to get equal legs)
 
Cont. Null
Off
 
Link
On
 
RPM
1500
 
Main/Filter Set-Up - 3rd Screen Special:
 
Probe Drive
Medium
 
Probe Canon
Lemo-16
 
Filter Type
Fig.8
 
Display Menu - 1st Screen:
 
Display Mode
Imp.
 
Channel
Freq.1
 
Position
Custom
 
H-Pos
50% (As Needed)
 
V-Pos
50% (As Needed)
 
Display Menu - 2nd Screen:
 
D. Erase
.1 Sec (As Needed)
 
Persist
Off
 
Cursor
Dot
 
Grid
10x10
 
Zoom
Off
 
Alarm Menu
Adjust as Needed
 
Rohmann Elotest M3
 
Frequency
2.0 MHz
 
Bandpass
400 Hz - 1.0 KHz
 
Gain
60 dB
 
Pre-Amp
Max possible
 
Y-Spread
0.0 dB
 
Phase
175°
 
Filter: High Pass
400 Hz
 
Filter: Low Pass
1.25 kHz
 
Hocking Phasec 2d / 2s / 3d / 3s
 
Power
On
 
Frequency
2.0 MHz
 
Filter
BP Lock (3d/3s)
 
Gain (X&Y)
41 dB
 
Phase
80
 
Input Gain
High
 
Probe
Reflection (3d/3s)
 
Hi-Pass (Filter)
250
 
Lo-Pass (Filter)
1500
 
Display
Spot
 
Probe Load uH
8.2 (3d/3s)
 
Probe Drive
+8 (3d/3s)
 
Trace Display - Graticule
Grid 2 (3d/3s)
 
Horizontal Position
50% (2D) As Required
 
Vertical Position
50% (2D) As Required
 
RPM
2000
(b)Probe rotors, associated cables, and adapters are listed in Table 2.
(c)Eddy Current Probe: SPO-5000 series or a GE-approved probe. The probe to be used will be specified in the appropriate approved Engine/Shop Manual or Service Bulletin for the specific hardware to be inspected.
NOTE:
If a different filter setting is specified in an Engine Shop Manual for a specific part, that setting must be used.
 
Probe Rotors, Associated Cables, and Adapters - Table 2
 
Instrument
Maker
Rotor
Adapter
Cable
Guide Fixture
 
Elotest B1
Rohmann
HF or STD
ARM-1*
RK-2N
GE-FQAP-302
 
Elotest B2
Rohmann
HF or STD
ARM-1*
RK-2N
GE-FQAP-302
 
Elotest B1V3/V4
Rohmann
HF or STD
ARM-1*
RK-2N
GE-FQAP-302
 
Elotest M3
Rohmann
HF or STD
ARM-1*
RK-2N
GE-FQAP-302
 
NDT 19/19e/19ell or Nortec 24
Staveley
19/RA
SPO-5201
9113660
GE-FQAP-302A
 
Nortec 2000 Series
Staveley
19/RA
SPO-5201
9122084
GE-FQAP-302A
 
NDT 19ell Nortec 24
Staveley
Spitfire 2000
Not Req.
9122091
GE-FQAP-302D
 
Nortec 2000 Series
Staveley
Spitfire 2000
Not Req.
9122090
GE-FQAP-302D
 
Nortec 500D / 500S / 600 / 600D / 600S
Staveley
Spitfire
Not Req.
9122090.00
GE-FQAP-302D
 
Nortec 500D / 500S / 600 / 600D / 600S
Staveley
Minnie Mite
Not Req.
9122089.02
GE-FQAP-302D
 
US-454/454A EddyVision
UniWest
JF-15
Not Req.
94142 JF-15
GE-FQAP-302E
 
Phasec 2d / 2s / 3d / 3s
Hocking
Hocking Mini
Not Req.
33A103
GE-FQAP-302F
 
(Rotor PN:33A100)
 
Elotest B1.V3/B1.V4
Rohmann
HF or STD
ARM-1*
RK-2N
GE-FQAP-502
 
Elotest B1.V3/B1.V4
Rohmann
HF or STD
ARM-1*
RK-2N
GE-FQAP-504
 
Phasec 1.1
Hocking
33A022
Not Req.
33A023
GE-FQAP-302B
 
2200
Hocking
33A106
Not Req.
33R103
GE-FQAP-302B
 
Defectoscope SD 2.832 AF 2.833
Forster
HRo 1500
Not Req.
Fixed
GE-FQAP-302C
 
Defectoscope SD 2.832 AF 2.833
Forster
HRo 860T
Not Req.
140-639-6
GE-FQAP-302C
 
NOTE:
* - an approved alternate is the RB1 M1 adapter (GK Engineering).
(d)Guide Fixture: An approved guide fixture must be used for all inspections to provide mechanical control of the probe angle. The guide fixtures are listed in Table 2 will be specified (by GE kit number) in the appropriate Service Bulletin or Engine/Shop Manual procedure. Refer to Figure 7.
(e)Calibration Standard: Calibration standards will be specified in the appropriate Service Bulletin or Engine/Shop Manual procedure for the part to be inspected. Refer to Figure 6.
(f)Mineral Oil: A small amount of mineral oil or other lubricant may be used to reduce friction for smoother probe rotation, reduced probe and standard wear, and less noise. It is important that the lubricant be a relatively inert material to avoid chemical reactions which may affect probe performance or reduce its useful life. The use of mineral oil or another lubricant is not required but is left to the discretion of the user.
(g)Cleaning Materials: Approved cleaning materials and solvents should be used to make sure the part is clean before inspection.
(h)Flex-Hones: Flex-Hones may be used when more aggressive cleaning is required and shall be specified in the appropriate Service Bulletin or Engine/Shop Manual procedure.
(i)Marking Materials: Action Marker Q404, black, or equivalent, shall be used to perform any marking of hardware.
(5)Pre-inspection Part Preparation.
(a)Clean the holes to be inspected in accordance with TASK 70-22-06-110-043, Special Cleaning Procedure No. 6, Bolthole Cleaning for Eddy Current Inspection.
(b)Number the holes for reference. The reference location for numbering is the “/” in the designation “S/N” where the part serial number is located. Hole number 1 is the first hole clockwise from the “/”, aft looking forward (ALF). If the “S/N” mark does not exist, the number 1 hole will be the first hole clockwise from the initial digit of the serial number. All remaining holes are then numbered in sequence moving clockwise, aft looking forward.
(c)Visually inspect the holes under white light. Clean the holes again, as required, to remove any remaining dirt or foreign material. TASK 70-22-06-110-043, Special Cleaning Procedure No. 6, Bolthole Cleaning for Eddy Current Inspection.
(6)Initial Equipment Setup.
(a)Select the appropriate inspection kit, as specified in the Service Bulletin or Engine/Shop Manual procedure for the hardware to be inspected.
NOTE:
Refer to Table 2 for instrument and tooling compatibility.
(b)Install the eddy current probe rotor into the appropriate guide fixture. Refer to Figure 5.
(c)Connect the cable from the probe rotor to the eddy current instrument.
(d)Insert the probe in the calibration standard hole to check the probe fit. Refer to Figure 6 and Figure 4. It is necessary that the probe contacts the surface of the hole but there should be no interference or binding. Significant probe drag may slow or stop the rotor.
(e)If the difference between the probe and hole diameters is too great, either too large or too small, it may be necessary to use a slightly larger or smaller probe.
NOTE:
It is not recommended to alter the probe ball diameter by any means.
(f)Insert the probe into the probe rotor or probe adapter, as appropriate for the type of rotor being used. Refer to Figure 5.
(g)Adjust the eddy current instrument to the initial settings, as specified in Table 1.
(7)Equipment Calibration.
(a)Turn on the probe rotor and apply a very small amount of mineral oil to the tip of the probe, if desired.
NOTE:
Spraying of oil from the spinning probe can be avoided by placing a small drop of oil on a fingertip and then briefly holding the finger against the probe tip.
(b)Place the guide fixture on the calibration standard, center it over the calibration hole, and translate the probe carefully into the hole.
(c)With the probe placed well into the calibration hole but away from the electric-discharge machined (EDM) notch, null (compensate) the instrument.
(d)Translate the probe through the hole until the notch signal is located. Refer to Figure 3.
(e)Scan the length of the EDM notch and observe the response on the CRT.
(f)Hold the rotor at the position where the largest notch signal response is obtained.
(g)Adjust the instrument phase (rotation) control to orient the notch signal vertically. Refer to Figure 3.
(h)Adjust the gain control to produce a notch signal with a vertical peak-to-peak amplitude of four major screen divisions. It may be helpful to offset the dot position from the center of the screen as an aid in setting the correct notch signal amplitude.
NOTE:
If the selected instrument gain adjustments are in 1 dB steps, it may not be possible to achieve a notch signal amplitude of exactly four major screen divisions. If the exact calibration amplitude cannot be obtained, use the next higher gain setting.
(i)Translate the rotor to scan the complete length of the notch to make sure that the calibration was performed at the location of the largest notch signal amplitude.
NOTE:
Two peaks will be obtained from most notches which have a length that is smaller than the probe sensing coil diameter. Check the amplitude of both peaks to make sure the calibration is performed on the peak which provides the largest response.
(j)Record the instrument calibration settings on the inspection data sheet, Form 699-1( Figure 2).
(8)Hardware Inspection.
(a)After completion of the instrument calibration, either the impedance plane (X/Y) or timebase (Y/T) display mode can be used during the inspection of hardware. Refer to Figure 3 and Figure 1. The gate and alarm may also be used if desired.
(b)Remove the probe from the rotor and check the probe fit by inserting the probe into several randomly selected holes around the hardware.
1It is necessary that the probe contacts the surface of the hole but there should be no interference or binding.
2If the selected probe does not meet the criteria described in the proceeding paragraph, the probe may be worn or the hole may be oversized. Another probe should be selected.
NOTE:
The eddy current probes used for this procedure are designed to expand and contract over the full range of the specified tolerance of the hole.
(c)Return the probe to the rotor and apply a small amount of mineral oil to the probe tip if desired. If required, adjust the leveling block at the bottom of the guide fixture to keep the probe perpendicular to the bolt hole.
(d)Carefully center the probe over the first hole to be inspected and translate the rotor until the probe coil is well into the hole.
(e)Null the eddy current instrument.
(f)Translate the probe slowly down through the hole and back up again while observing the display of the eddy current instrument. The translation speed should be approximately 0.2 inch (5 mm) per second or less. At this speed the inspection of a hole which is 1.0 inch (25 mm) deep should take at least five seconds in each direction.
(g)Monitor the eddy current instrument display and record any indications that exceed the inspection threshold requirements given in the appropriate Service Bulletin or Engine/Shop Manual procedure for the part being inspected.
(h)Move to each subsequent hole and repeat the inspection process. Periodically reapply mineral oil to the probe tip, if needed.
(9)Post-inspection Calibration Check.
(a)A calibration check shall be performed upon the completion of each inspection, at least every hour, whenever any system component or the inspector is changed, or any time the inspector suspects a change may have occurred in the inspection system.
(b)Return the guide fixture to the calibration standard. Center the fixture over the calibration hole, and move the probe carefully into the hole.
(c)With the probe well into the hole and the coil away from the EDM notch, null the instrument.
(d)Scan the length of the EDM notch and hold the rotor at the position where the largest notch signal response is obtained.
(e)If the notch response obtained is four major screen divisions, ± one-half major division, the test is acceptable.
(f)If the notch response has decreased by more than one-half major screen division, the system must be re-calibrated and any hardware inspected since the last acceptable calibration must be re-inspected.
(g)If the notch response has increased by more than one-half major screen division, the system must be re-calibrated prior to the inspection of any additional hardware. Hardware inspected and determined to be acceptable since the last acceptable calibration need not be re-inspected.
(10)Indication Evaluation/Rejection Criteria.
(a)Evaluate any hole which, during the initial inspection, produced one or more indications exceeding the indication evaluation/rejection threshold requirements given in the appropriate Service Bulletin or Engine/Shop Manual procedure for the part being inspected.
(b)Perform a calibration check as described in paragraph 2.A.(9), Post-inspection Calibration Check.
(c)Repeat the inspection of the hole to relocate the indication and confirm that it exceeds the evaluation/rejection threshold requirements.
(d)If the indication is confirmed, clean the hole using approved cleaning material. Refer to paragraph 2.A.(11), Cleaning Procedure.
(e)Visually inspect the hole and record any unusual conditions which might affect the inspection results on the eddy current inspection data sheet, Form 699-1( Figure 2).
(f)Repeat the inspection of the hole after cleaning. If the indication amplitude has reduced, repeat the cleaning process as necessary until the indication is removed or the amplitude of the eddy current indication is reduced below the evaluation/rejection limit.
(g)If the indication cannot be reduced in amplitude to an acceptable level, or increases in amplitude as a result of the cleaning process, refer to paragraph 2.A.(12), Disposition, Documentation, and Records, and the appropriate Service Bulletin or Engine/Shop Manual procedure for the disposition of the hardware.
(11)Cleaning Procedure.
(a)Refer to TASK 70-22-06-110-043 , Special Cleaning Procedure No. 6, Bolthole Cleaning for Eddy Current Inspection.
(12)Disposition, Documentation, and Records.
(a)Any indication equal to or greater than the criteria specified in the appropriate Service Bulletin or Engine/Shop Manual procedure for the hardware being inspected shall be evaluated to the requirements of paragraph 2.A.(10), Indication Evaluation/Rejection Criteria.
(b)If the amplitude of any indication, after evaluation, is still equal to or greater than the specified requirements, the hardware shall be considered reject and unserviceable.
(c)If the inspection produces no indications equal to or greater than the specified requirements, the hardware shall be considered serviceable.
(d)As a minimum, record the requested information on Form 699-1( Figure 2).
* * * FOR ALL
Figure 1   Calibration CRT Display - X/Y Timebase
* * * FOR ALL
Figure 2   High Speed Eddy Current Inspection Data Sheet
* * * FOR ALL
Figure 3   Calibration CRT Display - X/Y Impedance Plane
* * * FOR ALL
Figure 4   High Speed Bolthole Probe, SPO-5000 Series
* * * FOR ALL
Figure 5   Rotor Installed In Guide Fixture
* * * FOR ALL
Figure 6   Calibration Standard Drawing
* * * FOR ALL
Figure 7   Guide Fixture
3 . Slow Speed Eddy Current Inspection (Method B).
Subtask 70-32-07-250-012
E.Method B: Slow Speed Eddy Current Inspection Method.
(1)Scope.
(a)This document describes the equipment, technique and procedure required to conduct 2 MHz slow speed eddy current inspections of circular holes in Inconel and titanium alloy engine hardware for the detection of cracking. A service bulletin or shop manual procedure must provide the detailed information needed for inspection of specific parts.
(b)This document describes the general procedure and equipment which have been approved for the performance of slow speed eddy current hole inspections. Exceptions to this procedure may be required for specific cases where the procedure or equipment described here cannot be used or is not appropriate. Such exceptions should be obtained in writing from GE Aircraft Engines.
(2)Applicable Documents.
(a)Instruction manuals or other information provided by equipment manufacturers.
(b)National Aerospace Standard 410 (NAS 410), which replaces MIL-STD 410, and/or American Society of Non Destructive Testing specification ASNT-TC-1A (ASNT-TC-1A).
(c)The appropriate Service Bulletin or Engine/Shop Manual procedure.
(3)Personnel Requirements.
(4)Personnel performing this inspection must be certified in accordance with NAS 410, ASNT-TC-1A, Air Transport Association Specification No. 105 (ATA 105), or locally approved certification program.
(a)Personnel performing this inspection should receive practical training in the use of this procedure and must demonstrate proficiency in calibration of the inspection equipment, inspection of hardware, and evaluation of indications before the authority to accept and reject hardware is delegated.
(b)Any training which may be provided by GE Aircraft Engines for a technique requiring the performance of this inspection method does not imply that the personnel who receive that training have met the requirements for inspector certification in accordance with NAS 410, ASNT-TC-1A, or ATA 105.
(5)Equipment Requirements
NOTE:
Items (a) through (f) are to be supplied by the inspection site.
NOTE:
Items (g) through (l) can be obtained from GE Aircraft Engines. The correct service bulletin or shop manual inspection procedure will specify (by GE kit Number) the necessary tooling requirements.
(a)Eddy current instrumentation - one of the following types of equipment is required in order to accomplish these inspections or approved equivalent.
1Nortec Model NDT-19/19E Eddyscope.
2Nortec Model NDT-16 Eddyscope with Model A16-1 amplifier, Model 016-2 oscillator and either a Model F16-1 or Model FS16-1 or FS16-2 filter module.
3Rohmann Elotest B1 SDM Eddyscope with Probe socket B1-NOB3H or B1-ANO2.
4Nortec Model NDT-25L
(b)Strip chart recorder: One of the following types of equipment is required in order to accomplish these inspections, or approved equivalent. (All recorders must have a minimum of 2 channels.)
1Gould 220 recorder.
2Gould TA240 recorder with two 13-6615-10A signal conditioners.
3Gould Windowgraf with two 13-6615-10A signal conditioners.
4Graphtech WR3310 recorder with two AL 3301 signal conditioners.
5Graphtech WR7500 recorder with two AL3501 signal conditioners.
NOTE:
GE has evaluated the strip chart recorders listed above and found them capable of performing the inspection defined in this procedure. Alternate strip chart recorders are permitted for use if the calibration and the inspection can be performed as described in this procedure. It is the user's responsibility to determine that the strip chart recorder is acceptable and to establish the proper settings such that they are consistent with the intent of SPM 70-32-07, Method B, Slow Speed Bolt Hole Inspection.
(c)Strip chart recorder paper as required.
(d)Connecting cables as required for Eddy current instrument, strip chart recorder, scanners, and controllers.
(e)Bolthole Scanner: One of the following sets of scanner equipment is required to accomplish a bolt hole inspection.
1Nortec model PS-2M scanner with model PS-2 speed control.
2Nortec Model PS-3R scanner and PS-3T translator with respective controllers.
(f)A rigid fixture for holding the Nortec bolthole scanners. Refer to paragraph 3.A.(4)(e), Bolthole Scanner. The fixture must have provision for positioning the scanner over the bolt or air holes and provision for adjustment so that the probe body can be set parallel to the axis of the bolt or air hole.
(g)Inspection probe: GE-approved 2 MHz hole probe. Refer to Table 3. The correct probe size to be used will be given in the service bulletin or shop manual procedure for the part to be inspected.
 
2 MHz Bolt Hole Probes - Table 3
 
Probe No.
Probe Range
Rotation PS2-M
PS-3R
Translation PS-3T
 
GEC.100-S/2
0.100 - 0.104
60 RPM
100 RPM
1.00 in/min
 
GEC.105-S/2
0.105 - 0.109
60 RPM
100 RPM
1.00 in/min
 
GEC.110-S/2
0.110 - 0.114
60 RPM
100 RPM
1.00 in/min
 
GEC.115-S/2
0.115 - 0.119
60 RPM
100 RPM
1.00 in/min
 
GEC.120-S/2
0.120 - 0.124
60 RPM
100 RPM
1.00 in/min
 
GEC.125-S/2
0.125 - 0.129
60 RPM
100 RPM
1.00 in/min
 
GEC.130-S/2
0.130 - 0.134
60 RPM
100 RPM
1.00 in/min
 
GEC.135-S/2
0.135 - 0.139
60 RPM
100 RPM
1.00 in/min
 
GEC.140-S/2
0.140 - 0.144
60 RPM
100 RPM
1.00 in/min
 
GEC.145-S/2
0.145 - 0.149
60 RPM
100 RPM
1.00 in/min
 
GEC.150-S/2
0.150 - 0.154
60 RPM
100 RPM
1.00 in/min
 
GEC.155-S/2
0.155 - 0.159
60 RPM
100 RPM
1.00 in/min
 
GEC.160-S/2
0.160 - 0.173
60 RPM
100 RPM
1.00 in/min
 
GEC.169-S/2
0.169 - 0.183
60 RPM
100 RPM
1.00 in/min
 
GEC.179-S/2
0.179 - 0.193
60 RPM
100 RPM
1.00 in/min
 
GEC.189-S/2
0.189 - 0.204
60 RPM
97 RPM
0.97 in/min
 
GEC.200-S/2
0.200 - 0.216
60 RPM
92 RPM
0.92 in/min
 
GEC.212-S/2
0.212 - 0.229
60 RPM
87 RPM
0.87 in/min
 
GEC.225-S/2
0.225 - 0.243
60 RPM
82 RPM
0.82 in/min
 
GEC.239-S/2
0.239 - 0.258
60 RPM
77 RPM
0.77 in/min
 
GEC.254-S/2
0.254 - 0.274
60 RPM
72 RPM
0.72 in/min
 
GEC.270-S/2
0.270 - 0.292
60 RPM
68 RPM
0.68 in/min
 
GEC.288-S/2
0.288 - 0.311
60 RPM
64 RPM
0.64 in/min
 
GEC.307-S/2
0.307 - 0.332
60 RPM
60 RPM
0.60 in/min
 
GEC.328-S/2
0.328 - 0.354
56 RPM
56 RPM
0.56 in/min
 
GEC.350-S/2
0.350 - 0.378
53 RPM
53 RPM
0.53 in/min
 
GEC.374-S/2
0.374 - 0.404
49 RPM
49 RPM
0.49 in/min
 
GEC.400-S/2
0.400 - 0.432
46 RPM
46 RPM
0.46 in/min
 
GEC.428-S/2
0.428 - 0.462
43 RPM
43 RPM
0.43 in/min
 
GEC.458-S/2
0.458 - 0.495
40 RPM
40 RPM
0.40 in/min
 
GEC.491-S/2
0.491 - 0.530
37 RPM
37 RPM
0.37 in/min
 
GEC.526-S/2
0.526 - 0.568
35 RPM
35 RPM
0.35 in/min
 
GEC.564-S/2
0.564 - 0.609
33 RPM
33 RPM
0.33 in/min
 
GEC.605-S/2
0.605 - 0.653
30 RPM
30 RPM
0.30 in/min
 
GEC.649-S/2
0.649 - 0.701
28 RPM
28 RPM
0.28 in/min
 
GEC.697-S/2
0.697 - 0.753
26 RPM
26 RPM
0.26 in/min
 
GEC.749-S/2
0.749 - 0.809
25 RPM
25 RPM
0.25 in/min
 
GEC.805-S/2
0.805 - 0.869
23 RPM
23 RPM
0.23 in/min
 
GEC.865-S/2
0.865 - 0.934
21 RPM
21 RPM
0.21 in/min
 
GEC.930-S/2
0.930 - 1.004
20 RPM
20 RPM
0.20 in/min
 
GEC1.000-S/2
1.000 - 1.080
18 RPM
18 RPM
0.18 in/min
 
GEC1.076-S/2
1.076 - 1.162
17 RPM
17 RPM
0.17 in/min
 
GEC1.158-S/2
1.158 - 1.251
16 RPM
16 RPM
0.16 in/min
 
GEC1.247-S/2
1.247 - 1.347
15 RPM
15 RPM
0.15 in/min
 
GEC1.343-S/2
1.343 - 1.450
14 RPM
14 RPM
0.14 in/min
 
GEC1.445-S/2
1.446 - 1.562
13 RPM
13 RPM
0.13 in/min
(h)Calibration standard: Calibration standards must be made of the same material as the part to be inspected. Standards must have a hole with an electrical-discharge-machined (EDM) notch cut in the side. Specific details about the dimensions of the calibration standard, the diameter of the hole or holes, and the size and location of the EDM notch will be specified in the service bulletin or Engine/Shop Manual procedure, for the part to be inspected. See Figure 6.
(i)Marking materials: C05-104   Action Marker 44, black, or equivalent, to mark parts.
(j)Rubber wedge material: Parkway Products, G.E. RTV583, 0.375 in. (9.53 mm) sheet thickness or equivalent such as an eraser.
(k)Cleaning materials: Approved cleaning materials and solvents should be used to make sure the part is clean before inspection.
(l)Teflon tape: maximum thickness 0.0035 inch (0.089 mm) 3M Company, number 5490, 0.25 in (6.35 mm) wide.
(6)Pre-inspection - Part Preparation.
(a)Clean the holes using approved cleaning materials. Refer to TASK 70-22-06-110-043, Special Cleaning Procedure No. 6, Bolthole Cleaning for Eddy Current Inspection.
(b)Number the holes for reference. The reference location for numbering is the "/" in the designation "S/N" where the part serial number is located. Hole number 1 is the first hole clockwise from the "/", aft looking forward (ALF). If the "S/N" mark does not exist, the number 1 hole will be the first hole clockwise from the initial digit of the serial number. All remaining holes are then numbered in sequence moving clockwise, aft looking forward.
(c)Visually inspect the holes under white light. Clean the holes again, as required, to remove any remaining dirt or foreign material. Refer to TASK 70-22-06-110-043 , Special Cleaning Procedure No. 6, Bolthole Cleaning for Eddy Current Inspection. Note on the appropriate inspection data sheet any significant physical conditions in the holes such as evidence of fretting or rubbing.
(7)Equipment Set-up.
(a)Set the instrument control settings in accordance with Table 4.
(b)Set the Gould model No. 220 to the settings in accordance with Table 4, or alternate recorder in accordance with Figure 13.
(c)Adjust the rotational speed of the scanner so that it corresponds to the value noted in Table 3 for that diameter of bolt hole probe being used.
 
Initial Instrument Control Settings - Table 4
 
Control Description
Initial Settings
 
Elotest B1:
 
Frequency
2.0 MHz
 
Gain
40 dB
 
Y Axis Gain
0 dB
 
X Axis Gain
0 dB
 
Preamplifier
12 dB
 
Bandwidth
HF
 
Phase
0 degrees
 
Dot Position Y/X
0/0
 
NDT-16:
 
Filter
Lowpass 100 Hz
 
Gate
Off
 
Alarm
Off
 
Power switch
On
 
Rotation Control
0.0
 
Gain Control
2.00
 
Frequency Selector
2 MHz
 
X Control
Mid Range
 
R Control
Mid Range
 
Display Sensitivity
1V (H & V)
 
Null Button
-
 
Memory Control Features
Storage
 
CRT Adjustment Controls (at GRD)
Center Spot
 
Display Selector
Filter
 
Filter Out Switch
In
 
20 Hz Filter Switch
Out
 
10 Hz Filter Switch
Out
 
5 Hz Filter Switch
Out
 
Filter FS16-1 or 2 Modules:
 
Sweep Mode Switch
HV
 
Sweep Range Switch
Any
 
Sweep Speed Switch
Any
 
Sweep Trigger
Free Run
 
Erase Mode Switch
Manual
 
Record Mode Switch
Manual
 
Record Control Connector
-
 
Ext. Trigger Connector
-
 
Filter Out Switch
In
 
20 Hz Filter Switch
Out
 
10 Hz Filter Switch
Out
 
5 Hz Filter Switch
Out
 
NDT-19/19E:
 
Power
On
 
Control Lock
Off
 
Tape In
Off
 
Display
Frequency 1
 
Sweep
Off
 
Program
01
 
Memory 2
Off
 
Alarm
Off
 
Latch
Off
 
Frequency KHz
2000
 
Gain (Horizontal & Vertical)
51.0
 
Position (Horizontal & Vertical)
128
 
Angle (Rotation)
00
 
Filter - High Pass
0
 
Filter - Low Pass
100
 
SP 01, 03, 04, 05
Off
 
SP 02 (Probe Drive)
2 or High
 
Continues Null
Off
 
F1/F2 (Frequency)
Frequency 1
 
NDT 25L:
 
Power
On
 
Status Lights
On
 
Alarm
Optional
 
Display:

 
H/T
Off/NA
 
V/T
Off/NA
 
H/V
On
 
Non Store
Off
 
Alarm Size
NA
 
Alarm Pos
NA
 
Man X
As Needed
 
Man R
As Needed
 
Functions:

 
V Read
Off
 
H Read
Off
 
V Sens
1
 
H Sens
1
 
Frequency
2000 kHz
 
Angle
As Needed
 
Gain
50 dB
 
Prog Store
As Needed
 
Call Prog
As Needed
 
Filters:

 
High Pass
0 Hz
 
Low Pass (special function)
100 Hz
 
Gould 220 Recorder:
 
Vertical Pen Position
Centered
 
Horizontal Pen Position
Centered
 
Horizontal Fine Sensitivity
Full CW
 
Vertical Fine Sensitivity
Full CW
 
Horizontal Coarse Sensitivity
50mv/div
 
Vertical Coarse Sensitivity
20mv/div
 
Horizontal/Vertical Markers
Off
 
Recorder Power Button
On
 
Chart Stop Button
In
 
Chart Speed Selectors
Out
(d)Figure 13 provides equivalent settings for times when alternate recorders are used instead of the Gould 220. To use this table, refer to the Gould 220 initial settings in Table 4, find that setting in Figure 13 for the 220 then read across the table for the appropriate setting for the selected recorder.
NOTE:
Some inspection procedures require long term storage of strip chart recordings in excess of five (5) years. In these cases, the Gould 220 must be used and not the alternates, since the alternates listed in this document use thermal recording paper with a recorded shelf life limited to five (5) years.
NOTE:
It is the user's responsibility to assure that the recording medium complies with the appropriate regulation.
(e)For inspections being accomplished with a Nortec PS-3TR scanner, adjust the speed of translation on the PS-3T controller so that it has the value noted in Table 3 for the diameter of hole under inspection.
NOTE:
For smaller diameter bolt hole probes, adjust the rotational speed of the scanner to the maximum if the speed noted on Table 3 can not be achieved.
(f)Connect the vertical output of the eddy current instrument to Channel No. 1 of the strip chart recorder and the horizontal output of the eddy current instrument to Channel No. 2.
(8)Probe Preparation.
(a)Select the appropriate size probe for the hole to be inspected as specified in the applicable service bulletin or shop manual procedure. Refer to Table 3.
(b)Apply teflon tape to completely cover coil face. See Figure 12.
NOTE:
There must be no wrinkles in the tape edges or they will snag on entering the hole. If the tape is wrinkled, it is too wide or was improperly applied. Remove it, cut a narrower piece, and apply the new piece.
(c)Manually insert the probe into the calibration hole to determine fit. Proper fit is achieved when the probe tip is snug enough that it will stand alone and supports it's own weight. On inserting or withdrawing the probe there should be a light drag.
(d)For probes with saw slots, proper fit is obtained by cutting a piece of wedge rubber, at a slight wedge shape. Gross wedge shapes will work themselves out of the probe slot. Insert the rubber wedge into the probe slot and adjust for fit as described in paragraph 3.A.(7)(c). See Figure 11.
(e)For probes without saw slots, proper fit is obtained by applying teflon tape as required to the probe body opposite the coil.
(f)Insert probe into scanner.
(9)Equipment Calibration.
CAUTION:
BEFORE REMOVING ANY MODULE IN A NDT-16, TURN OFF THE INSTRUMENT POWER. MODULE DAMAGE MAY RESULT IF THE POWER IS NOT TURNED OFF.
(a)Connect the equipment and set the initial control settings per paragraph 3.A.(6) of this document.
1Set up the NDT-16 as follows:
aRemove the No. F16-1 filter module during set up of the equipment and carefully snap off the left side cover of the module.
bMove the small slide switch inside the module near the front panel to position X1.
cReplace the cover and reinsert the filter module.
2Set up the Elotest B1 as follows:
aDetermine the maximum possible preamplifier gain by increasing the preamplifier gain until the "PREAMP OVERLOAD" indication appears.
NOTE:
To minimize instrument produced noise, the preamplifier gain should be increased to the maximum possible value without producing a preamplifier overload condition.
bReduce the preamplifier gain just enough to eliminate the overload indication.
CAUTION:
DO NOT PRESS THE COMPENSATION BUTTON AFTER SWITCHING BACK TO THE LOW-PASS FILTER.
cTo operate at higher preamplifier gain levels, tune the impedance bridge circuitry. Set the filter to 100 Hz high-pass and press the compensation (null) button. Change the filter back to 100 Hz low-pass.
dPlace the probe on a test piece or calibration standard.
eAdjust the two small potentiometers on the adapter to move the dot as close as possible to the null point on the display.
NOTE:
If the dot position function is set to 0/0 then the null point will be at the center of the display.
fIf necessary, reduce the gain to bring the dot on screen so that this adjustment may be made.
NOTE:
With proper bridge adjustment it is possible to operate at high pre-amplifier gain settings. This adjustment may be different for each probe. After completing this adjustment, the compensation button can be used as needed to null the instrument.
3No special preparation is necessary for the Nortec NDT 19, NDT 19E, or NDT 25L.
(b)Prepare the probe as stated in paragraph 3.A.(7) of this document.
(c)Align the probe and scanner for correct entry into the hole with the calibration notch. Refer to 3.A(4)(h) calibration standard.
(d)Turn on the PS-2M or PS-3T and 3R probe scanner and drive the probe down into the calibration hole until the probe coil is completely within the hole.
(e)Stop the scanner when the white epoxy line on the probe stem faces away from the EDM slot location.
(f)Null the instrument. For NDT-16, null for 5 to 10 seconds or until the spot stabilizes in the center of screen.
(g)With the probe still in the calibration hole, turn on the PS-2M (FWD) and put the transmission in R for rotate only. For PS-3T and 3R systems, turn on the PS-3R for probe rotation only.
(h)Change the filter on the eddy current instruments:
1On the NDT 16, set the filter to 5 Hz (high pass).
2On the NDT 19 and 19E, leave the low pass filter at100 Hz, and set the high pass filter to 4 Hz or 5 Hz.
3On the Elotel B1, change the filter from the low pass100 Hz to high pass 5 Hz.
4On the NDT 25L, leave the low pass filter (SP-02) at 100 Hz, and set the high pass filter to 5 Hz.
(i)Turn on the strip chart recorder and check that Channel No. 1 is on 20 mV/Div. and Channel No. 2 is on 50 mV/Div.
(j)Translate the probe within the calibration hole until the EDM notch is detected.
(k)Manually translate the rotating probe across the entire EDM notch 0.003 in. (0.08 mm) at a time to determine where the maximum amplitudes are achieved on Channel No. 1 and No. 2.
(l)Observe the EDM notch response on the eddyscope. Adjust the rotation or phase control to obtain an EDM notch response pointing(longest leg) into the upper left quadrant of the CRT for Inconel or into the lower left quadrant of the CRT for Titanium. See Figure 10 and Figure 9. In both instances the phase angle established by this step should be set to approximately 45 degrees from horizontal.
(m)Examine the recorder tracings on Channels No. 1 and No. 2. Alternately adjust the rotation (Phase) and gain controls to achieve calibration amplitudes of 40 percent (400 mV) full scale on Channel No. 1 and 35 percent (875 mV) full scale amplitude in Channel No. 2 (plus or minus 1 percent full scale). Renull is required after any gain adjustment. Assure that the EDM notch response remains in the correct quadrant on the eddyscope.
NOTE:
For renulling, it is required that the coils face the side of the hole away from the EDM notch.
NOTE:
For calibration standards with correction factors applied to them, calibrate the equipment to those factors (plus or minus1 percent full scale).
NOTE:
Calibration standard correction factors - As a result of differences in notch response resulting from possible variations in the fabrication process, calibration standards may have amplitude correction factors (equivalent responses) applied to them. The GE quality technology laboratory will establish these equivalent responses by comparing the responses from the GE master standard to the response from the subordinate standard. In cases where an equivalent response is required, this equivalent response applies only to the calibration and does not alter the amplitudes specified for indication rejection or evaluation limits.
(n)When these amplitudes have been achieved, translate the probe very slowly across the entire notch to assure that the calibration has been performed at the point of maximum response from the notch. If a greater amplitude is obtained on the strip chart Channel No. 1 (vertical), repeat paragraphs 3.A.(8)(m) and (n).
(o)If excessive noise is experienced on Channel No. 1 at the calibration settings, check for the following:
1Teflon tape on probe face worn or damaged.
2Probe not aligned with calibration hole.
3Probe not wedged properly.
4Calibration hole dirty.
5Equipment malfunction (high gain).
(p)Record all calibration data onto the strip chart recording and onto an appropriate inspection data sheet. See Figure 8.
(10)Part Inspection
(a)Assure the teflon tape is still covering the coil. Replace if it is worn or wrinkled, and recheck calibration.
(b)Examine the probe fit in several holes and make whatever adjustments are necessary to ensure a fit which is equivalent to that obtained for calibration. Holes may be over or undersize and it may be desirable to inspect all the holes of one size before changing the diameter of the probe if it is required.
(c)Scan all holes in the upward direction (translation) unless otherwise specified.
NOTE:
Check the teflon tape on the probe frequently and replace it if it becomes worn or wrinkled.
(d)If any indications exceeding the requirements of paragraph3.A.(11) of this document are found, mark the hole for evaluation.
(e)After all holes have been inspected, evaluate the indications from paragraph 3.A.(9)(d) per paragraph 3.A.(12) of this document.
(f)Complete the post-inspection check per paragraph 3.A.(10) of this document.
(11)Post-inspection Calibration Check.
(a)After completion of the part inspection, or after intervals not to exceed four hours, check the calibration on the calibration standard.
(b)If the calibration repeats within ±5 percent of full scale at channel No.1 of the strip chart recorder the test is acceptable.
(c)If the amplitude of the response on Channel No. 1 has decreased by 5 percent of full scale amplitude, repeat the calibration procedure and reinspect all parts inspected since the previous calibration.
(d)If the amplitude of the response on Channel No. 1 has increased by more than 5 percent, only parts previously found to be rejected to paragraph 3.A.(11) need to be reinspected, repeat the calibration procedure prior to additional inspection.
(12)Inspection Requirements.
(a)Any indication equal to or greater than the criteria specified in the service bulletin or Engine/Shop Manual procedure for the part being inspected must be evaluated according to the requirements of paragraph 3.A.(12).
(b)If, after completion of the evaluation procedure, the amplitude of any indication is still equal to or greater than the requirements of the service bulletin or Engine/Shop Manual procedure, the part must be considered unserviceable.
(13)Indication Evaluation.
NOTE:
The optimum time to perform these evaluations is either at the time the indication is found, or immediately after the completion of the inspection of a specific area.
(a)Examine the traces on Channel No. 1 of the strip chart for each hole. For each hole with an indication(s) meeting the requirements of paragraph 3.A.(11), reclean the hole with a cotton swab moistened with cleaning fluid, and reinspect the hole. If the indication remains, it is considered repeatable, and should be evaluated as stated below. If not, proceed to next indication.
(b)For all repeatable indications record the hole number, Channel No. 1 amplitude on the recorder and the location within the hole on the appropriate inspection data sheet.
(c)Carefully examine the area under evaluation with a bright white light, using a glass of 2 to 10 power. Note any unusual conditions, such as discoloration, scratches, score marks, sharp edges, uneven surfaces, etc. Record these conditions on the appropriate inspection data sheet.
(d)Carefully reclean the area containing the indication per paragraph 3.A.(5) of this document. Assure that no protruding material exists in the area.
(e)Check that the probe fits snugly in the hole, and that the hole has not become elliptical.
(f)Assure that the calibration amplitude is 40 percent full scale on Channel No. 1 and 35 percent full scale amplitude on Channel No. 2. Assure that the EDM notch is in the correct quadrant on the eddyscope.
(g)Repeat the inspection of the hole. If the indication amplitude has reduced, repeat the cleaning process as necessary until the indication is removed or the amplitude of the eddy current indication is reduced below the evaluation limit.
(h)If the indication cannot be reduced in amplitude to an acceptable level, or increases in amplitude, as a result of the cleaning, refer to paragraph 3.A.(11) and the appropriate service bulletin or shop manual procedure for information regarding the disposition of the part.
(14)Records
(a)As a minimum, the following information must be permanently written on each strip chart recording and an appropriate inspection data sheet.
 
Item
Data To Be Recorded
 
1 Eddyscope:
Manufacturer
Model No.
Serial No.
Gain level
Frequency setting
Rotation control setting
Filter switch position
 
2 Recorder:
Manufacturer
Serial No.
Horizontal channel coarse sensitivity
Vertical channel coarse sensitivity
Chart speed
 
3 Probe:
Model number, frequency designation, and serial number
 
4 Indications:
Evaluation of all reportable indications and results
 
5 Part:
Part Name
Part Number
Part Serial Number
Engine Serial Number
Type of Inspection and area.
Example: Inner Bolt Holes
Cycles Since New/Time Since New
(CSN/TSN) if available
* * * FOR ALL
Figure 8   Slow Speed Eddy Current Inspection Data Sheet
* * * FOR ALL
Figure 9   Titanium Notch Response
* * * FOR ALL
Figure 10   Inconel Notch Response
* * * FOR ALL
Figure 11   Rubber Wedging for Sizing
* * * FOR ALL
Figure 12   Application of Teflon Tape to Probe
* * * FOR ALL
Figure 13   (Sheet 1) Alternate Strip Chart Recorder Settings
* * * FOR ALL
Figure 13   (Sheet 2) Alternate Strip Chart Recorder Settings
4 . High Speed Eddy Current Inspection Method with Electronic Data Acquisition and Storage (Method C).
Subtask 70-32-07-250-013
F.Method C: High Speed Eddy Current Inspection with Electronic Data Acquisition and Storage.
(1)Scope.
(a)This document describes the equipment, technique, and procedure necessary to perform a 2 MHz high speed eddy current inspection with electronic data acquisition of circular holes in engine hardware. A Service Bulletin or Engine/Shop Manual procedure shall provide the detailed information needed for inspection of specific parts.
(b)Perform the inspection of the hardware in accordance with Subtask 70-32-07-250-011, High Speed Eddy Current Inspection (Method A), and the following parameters.
(2)Applicable Documents.
(a)All documents listed in paragraph 2.A.(2), Applicable Documents, are to be followed. Refer to Subtask 70-32-07-250-011, High Speed Eddy Current Inspection (Method A).
(3)Personnel Requirements.
(a)Personnel performing this inspection must be certified in accordance with one of the requirements listed in paragraph 2.A.(3), Personnel Requirements. Refer to Subtask 70-32-07-250-011, High Speed Eddy Current Inspection (Method A).
(4)Pre-inspection Part Preparation.
(a)Pre-inspection part preparation is to be performed in accordance with Subtask 70-32-07-250-011 , High Speed Eddy Current Inspection (Method A).
(5)Equipment Requirements.
CAUTION:
THE HOLESCAN SYSTEM IS A HIGH PERFORMANCE, PC-BASED EDDY CURRENT ELECTRONIC DATA ACQUISITION SYSTEM. DO NOT INSTALL ANY OTHER SOFTWARE (GAMES, SCREEN SAVERS, ETC.) OR HARDWARE (NETWORK CARDS, GAME CARDS, ETC.) WITHOUT APPROVAL FROM THE SYSTEM MANUFACTURER.
(a)Holescan system: Rohmann GmbH ScanAlyzer or a GEAE-approved equivalent. The Holescan/ScanAlyzer eddy current inspection system is a universal software program to analyze, record and file data of image generating eddy current inspections. The ScanAlyzer system includes the following recommended components:
1Computer - IBM-compatible PC, with Pentium processor > 200 MHz, main memory > 32 MB, monitor - SVGQ graphic card (256 colors > 800 x 600 pixel) 1024 x 786 recommended, operating system - Windows NT operating system with Service Pack 3 or higher, Elotest PC4 digitizing PC-card (type PC4/0, PC4/1, or PC4/2) and all associated software, or an approved equivalent.
2Eddy current instrument - Rohmann Elotest B1/V4 or latest version with model B1-RS probe adapter.
3Guide fixture - A GEAE-approved guide fixture, P/N SO16602, to provide mechanical control of the probe angle.
4Probe rotor - SR1-HF Rohmann ScanAlyzer rotation scanner with analog or digital position identification, or an approved equivalent.
5Cable - Rohmann GmbH model RK-2N cable, or an approved equivalent.
6Probe Adapter - ARM1 for Rohmann rotor, or an approved equivalent.
(b)Probe: GE Aircraft Engines (GEAE) SPO-5000 series probe or an approved equivalent. The correct probe size will be specified in the Service Bulletin or Engine/Shop Manual procedure for the part to be inspected. Refer to Figure 4.
(c)Calibration Standard: Calibration standards must be made of the same material as the part to be inspected. Specific details will be specified in the Service Bulletin or Engine/Shop Manual procedure for the part to be inspected. Refer to Figure 6.
(d)Mineral Oil: A small amount of mineral oil or other GEAE-approved lubricant can help produce a smoother probe rotation, reduce probe wear, and reduce incorrect eddy current signals. It is important that the lubricant be a relatively inert material to avoid chemical reactions that may affect probe performance or reduce its useful life. The use of mineral oil or another lubricant is not necessary but can be used at the discretion of the inspector.
(e)Cleaning Materials: Use GEAE-approved cleaning materials and solvents to make sure the part is clean before inspection.
(f)Marking Materials: Action Marker P/N Q404, black, or a GEAE-approved equivalent, to mark parts.
(g)Flex-Hones: Flex-Hones may be used when more aggressive cleaning is required and shall be specified in the appropriate Service Bulletin or Engine/Shop Manual.
(h)Inspection Shoes: A dedicated inspection fixture (shoe) for each piece of hardware has been designed to help facilitate inspection of the boltholes. It is recommended that inspection be performed using the inspection shoes. A list of approved inspection shoes can be obtained from GEAE.
(6)Initial Equipment Setup.
(a)Make all necessary cable connections for system operation.
(b)Select the appropriate eddy current probe and calibration standard for inspection.
(c)Insert the probe into the calibration standard hole to check the fit. It is desirable to have the probe lightly touch the surface of the hole but there should be no interference or binding. The motor in the probe rotor is very low torque so any drag will slow or stop the rotor.
1If the difference between the probe and hole diameter is too great, either too large or too small, it may be necessary to use a slightly larger or smaller probe.
(d)Insert the probe into the probe rotor.
CAUTION:
TURN OFF THE POWER TO THE ROHMANN EDDY CURRENT INSTRUMENT WHEN IT IS NOT IN USE. DAMAGE TO THE CATHODE RAY TUBE (CRT) MAY OCCUR WHEN IT IS NOT USED FOR MORE THAN ONE HOUR.
(e)Adjust the Rohmann Elotest B1/V4 controls in accordance with the settings given in Table 5.
(f)Adjust the Holescan system controls:
1Using the DEVICE SETUP menu in the APPLICATIONS MANAGER menu, adjust the ScanAlyzer controls in accordance with the settings given in Table 6, Table 7, and Table 8.
(g)Recommended filter settings for certain probe diameters are given in Table 9.
NOTE:
Filter settings are based upon probe diameter. The settings may change over time because of probe wear. The table below is a reference to use as a starting point for filter settings. Because of probe manufacturer, conditions, and diameter, some adjustment to these settings may be necessary to achieve equal lengths of the eddy current signal legs.
 
Rohmann Elotest B1/V4 Controls - Table 5
 
Description
Initial Setting
 
Frequency
2 MHz
 
BWL
Off
 
Gain
60 dB
 
Pre-amp
Increase until probe trouble/overload is detected by the instrument, and then reduce the pre-amp by one setting
 
X Axis Gain
0 dB
 
Y Axis Gain
0 dB
 
Phase
186
 
Disp
Y/X
 
Highpass Filter
See Filter Settings Table
 
Lowpass Filter
See Filter Settings Table
 
Band
Dyn (600-850 Hz band pass)
 
Dot Position
0/0
 
Timebase
SYNC - Auto
 
Gate
Optional
 
Alarm
Optional
 
NOTE:
The initial settings of the MAIN PARAMETERS dialog box in the INSTRUMENT menu can be downloaded to and/or from the Rohmann Elotest B1/V4 instrument.
 
Holescan System Controls, INSTRUMENT Menu - Table 6
 
Description
Setting
 
DISPLAY Window:

 
Threshold Type
Cross Threshold (Box)
 
Threshold Level X-Axis (Cross/Box)
250/250
 
Threshold Level Y-Axis (Cross/Box)
100/100
 
Alarm Mode
Short (Visible)
 
Timebase
Auto
 
X-deflection
25ms/div
 
Single Shot Time
0.3 sec
 
Roll Mode Time
8s
 
Holescan System Controls, SCAN DEVICE Menu - Table 7
 
X-Axis
Y-Axis
Info
 
PC4 SCANNER PARAMETERS Window:
 
Meter Mode
Rotor Double (rotor checked)
Meter Mode
Analog (fixed lines checked)
Data Source
Channel 1 (ext)
 
Meter Unit
Degrees
Meter Unit
(Inches)


 
Start Position
0
Start Position
0


 
End Position
360
End Position
2.165354


 
Scan Resolution
0.5
Scan Resolution
0.015


 
Physical Resolution
0.5
Physical Resolution
0.000528651


 
Max Scan Speed
3600




 
NOTE:
AXIS dialog box in the DISPLAY menu is not used for set up of ScanAlyzer.
 
Holescan System Controls, DISPLAY Menu - Table 8
 
Standard DISPLAY Configuration Window:
 
Adjust Default Volt/Div.
0.5 V/Div.
 
C-Scan Unit
Use Div.
 
Recommended Filter Settings - Table 9
 
Probe Diameter (Inch)
Highpass Filter (Hz)
Lowpass Filter (Hz)
 
0.192
200
800
 
0.239
200
800
 
0.244
200
800
 
0.247
200
800
 
0.281
400
1000
 
0.294
400
1000
 
0.299
400
1000
 
0.308
400
1000
 
0.314
400
1000
 
0.318
400
1250
 
0.328
400
1250
 
0.334
400
1250
 
0.395
500
1250
 
0.408
500
1250
 
0.435
500
1250
 
0.514
500
1250
(7)Equipment Calibration.
NOTE:
The eddy current instrument displays the peak-to-peak eddy current signal. The ScanAlyzer system captures the peak response of the longest leg of the eddy current signal, not the peak-to-peak value. Any calibration response from the ScanAlyzer system must be doubled for the correct calibration amplitude.
(a)Equipment calibration is to be performed in accordance with Subtask 70-32-07-250-011, High Speed Eddy Current Inspection (Method A).
(8)Hardware Inspection.
(a)Attach the appropriate inspection shoe to the guide fixture for inspection of boltholes.
(b)Hardware inspection is to be performed in accordance with Subtask 70-32-07-250-011, High Speed Eddy Current Inspection (Method A).
(9)Post-inspection Calibration Check.
(a)Remove the inspection shoe from the guide fixture before post-inspection calibration check.
(b)Post-inspection calibration is to be performed in accordance with Subtask 70-32-07-250-011, High Speed Eddy Current Inspection (Method A).
(10)Indication Evaluation/Rejection Criteria.
NOTE:
The eddy current instrument displays the peak-to-peak eddy current signal. The ScanAlyzer system captures the peak response of the longest leg of the eddy current signal, not the peak-to-peak value. Any evaluation performed of an eddy current response from the ScanAlyzer system must be doubled for the correct amplitude.
(a)Evaluation and rejection of hardware is to be performed in accordance with Subtask 70-32-07-250-011 , High Speed Eddy Current Inspection (Method A).
(11)Cleaning Procedure.
(a)Refer to TASK 70-22-06-110-043 , Special Cleaning Procedure No. 6, Bolthole Cleaning for Eddy Current Inspection.
(12)Disposition, Documentation, and Records.
(a)Disposition, documentation, and record keeping are to be performed in accordance with Subtask 70-32-07-250-011, High Speed Eddy Current Inspection (Method A).